220vac to 110v dc 400w switching power supplies
Description:
KH-400-110 model is 400W switching power supply that has high efficiency, 110V 220V AC input by switch and 110V output voltage adjustable with 2 years warranty, it can used in industrial automation products.
Features:
1,400W power supply with high efficiency and low temperature rise;
2,110V 3.6A power supply with wide range of ac input voltage;
3,DC 110V 400w power supply have temperature-controlled fan;
4, 400W 110V SMPS with short circuit,overload, overvoltage and over temperature protection.
Parameter
|
Item No.
|
KH-400-110
|
Output
|
Output Voltage
|
+110V
|
Rated Current
|
3.6A
|
Current Range
|
0-3.6A
|
Rated power
|
396W
|
Ripple
|
1Vp-p
|
Adjustable output range
|
±10%
|
Output Accuracy
|
±1%
|
Line Regulation
|
±0.5%
|
Load Regulation
|
±0.5%
|
Set up,Rise,Keep up time
|
50ms,50ms,20ms
|
Input
|
Input Voltage range
|
90~132V/180~264V AC;200~360V DC
|
Input current
|
6A/115V;3A/230V
|
Input frequency
|
47~63Hz
|
Efficiency
|
88%
|
Inrush current
|
30A@230V
|
Leakage Current
|
<0.5mA@240V
|
Protection
|
Over load
|
105~150%,As of protective, recovery after power failure
|
Short circuit
|
As of protective, recovery after power failure
|
Output overvoltage
|
------
|
Over Temp.
|
>90℃,shut down
|
Others
|
Temp. Controlled by fan
|
NTC2>55℃,fan running;<45℃,fan stopping
|
Environment
|
Working Temp.,Humidity
|
-10~60℃,10~90% RH,No condensation
|
Storage Temp.,Humidity
|
-20~85℃,10~95% RH
|
Temp.,Drift
|
±0.03%/℃(0~50℃)
|
Vibration
|
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
|
Safety&EMC Standards
|
Safety standards
|
GB4943
|
Pressure
|
I/P-O/P,I/P-FG:1.5KV;O/P-FG:0.5KV DC 1min.
|
Insulation resistance
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
|
EMC standards
|
GB9254,EN55022 CLASS B
|
Others
|
Demension
|
215*115*50mm CASE:K810
|
Weight
|
1.0Kg
|
Note
|
1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured.
|
Product picture: