250kW-500kW V5 Series High Performance Universal Inverter

As the VFD manufacturer in china, V&T V5-H series is a high-performance vector control inverter. The product adopts open-loop vector control technology ;which is completely synchronized with the most advanced technology in the world. It has the excellent control performance with the international high-end frequency drive.


  • Shipping PortShenzhen
  • Place of OriginChina
  • Warranty18 Months
  • Delivery Time5-7 working days for standard series; 7-14 working days for customized AC drives
  • PackageStandard Export Package Carton/Wood
  • AvailabilityOEM/ODM, Minmum Order Request
  • TransportationExpress · Sea freight · Land freight · Air freight
  • CustomizedYES
  • Term of paymentT/T, L/C, D/P
  • Sample freight payerBuyer
  • Sample provideYES
  • CertificationCE, EAC, ISO9001, OHSAS18001, TS16949, SGS

Product Overview

Item Description
Product Name Frequency Inverter/ AC Drive
Model Number V5-H-4TxxG/xxL
Power Range 0.75kW-75k0W
Rated Input Voltage 3 phase 380V/480V
Rated Output Voltage 3 phase 0 to rated input voltage
Input Frequency 50Hz/60Hz
Adaptable Motor Asynchronous Motor
Control Mode V/F Control, Vector Control, Sensorless Vector Control, Vector Torque Control
Communication Modbus 485 RTU
IP Class Standard IP20
Overload Capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)

Feature

■ Open loop vector control technology with high performance.

■ Inverter operates stably without tripping under any acceleration and deceleration time and any impact load.

■ Independent input and output port of high speed pulse, which can realize high speed pulse cascade function.

■ Accurate speed identification and rotor flux orientation, the torque can also respond quickly and operate stably when a load of 0.25hz breaks.

■ High-precision current detection and protection, high-precision hall to detect output current, realization of fast real-time control and protection of software and hardware, and assurance of performance and reliability of the whole machine.


Model Explanation



Product Catalogue

V5−H−4T□□□G Three-phase 400V Constant torque/heavy-duty application

Power (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Motor power (kW) 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Output Voltage (V) Three-phase 0 to rated input voltage
Rated current (A) 2.5 3.8 5.5 9 13 17 24 30 39 45 60 75 91 112 150
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag ;feature)
Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range 323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 2.8 4.2 6.1 10 15 19 26 33 43 50 66 83 100 123 165
Braking unit Built-in as standard Built-in as option
Protection class IP20
Cooling mode Natural−cooling Forced air cooling
Power (kW) 90 110 132 160 185 200 220 250 280 315 355 400 450 500
Motor power (kW) 90 110 132 160 185 200 220 250 280 315 355 400 450 500
Output Voltage (V) Three-phase 0 to rated input voltage
Rated current (A) 176 210 253 304 350 380 426 470 520 600 650 690 775 860
Overload capacity 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag ;feature)
Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range 323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 160* 196* 232* 282* 326* 352* 385* 437* 491* 580* 624* 670* 755* 840*
Braking unit External braking unit needed
Protection class IP20
Cooling mode Forced air cooling
*V5−H−4T90G and higher power products are equipped with external DC reactor as standard.


V5−H−4T□□□L Three-phase 400V Variable torque/light-duty application

Power (kW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Motor power (kW) 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Output Voltage (V) Three-phase 0 to rated input voltage
Rated current (A) 3.3 5 7.5 11 17 22 30 37 44 56 72 91 110 142 176
Overload capacity 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage fluctuation range 323V ~ 528V; Voltage imbalance: ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 3.6 5.5 8.3 12 19 25 33 40 50 62 80 100 121 156 194
Braking unit Built-in as standard Built-in is optional
Protection class IP20
Cooling mode Natural cooling Forced air cooling
Power (kW) 110 132 160 185 200 220 250 280 315 355 400 450 500 560
Motor power (kW) 110 132 160 185 200 220 250 280 315 355 400 450 500 560
Output Voltage (V) Three-phase 0 to rated input voltage
Rated current (A) 210 253 304 350 380 426 470 520 600 650 690 775 860 950
Overload capacity 115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input Rated voltage/frequency Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range 323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 196* 232* 282* 326* 352* 385* 437* 491* 580* 624* 670* 755* 840* 920*
Braking unit External braking unit needed
Protection class IP20
Cooling mode Forced air convection cooling
*V5−H−4T110L and higher power products are equipped with external DC reactor as standard.


V5−H−2T□□□G Single/Three-phase 200V Constant torque/heavy-duty application

Power (kW) 0.4 0.75 1.5 2.2
Motor power (kW) 0.4 0.75 1.5 2.2
Output Voltage (V) Three-phase 0 to rated input voltage
Rated current (A) 3 5 7.5 10
Overload capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes ;
(inverse time lag feature)
Input Rated voltage/frequency Three-phase or single-phase 200V~240V; 50Hz/60Hz
Allowable voltage range 180V ~ 260V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5%
Rated current (A) 3.8 5.5 8.3 12
*Braking unit Built-in as standard
Protection class IP20
Cooling mode Natural-cooling Forced air cooling


Technical Specification

Control characteristics

Control mode

Vector control 1

Vector control 2 (Without encoder)

Starting torque

0.50Hz  180%

0.25Hz  180%

Range of speed regulation

1:100

1:200

Precision of steady speed

± 0.5%

± 0.2%

Product functions

Key functions

Under-voltage regulationswitchover of run command source(operation panel, terminal and communication), speed tracing function, torque limit, multi− step frequency reference(up to 23 step frequency), motor data identification, S curve acceleration and deceleration, slip compensation, PID regulation, droop control, current limit, switch-over between torque control and speed controlmanual torque boost and auto torque boost, programmable digital inputs and programmable digital outputs

Frequency reference mode

Parameter setting, operation panel UP/DNterminal, terminal UP/DN, communication, analog ( AI1/AI2/AI3), pulse DI , etc.

Frequency range

0.00 ~ 300.00Hz   

Note:

In the control mode of vector control 1, frequency range from 0.0Hz to 3000.0Hz can be customized according to the customer demand

Start frequency

0.00 60.00Hz

Acceleration time and deceleration time

0.1 36000s

Dynamic braking 

Braking unit action voltage: 650 ~ 750V; operating time: 100.0s

The braking unit can be built-in for V5−H−4T75G and below equipment

DC braking

DC braking start frequency: 0.00 ~ 300.00Hz

DC braking current: constant torque: 0.0 120.0%, variable torque: 0.0 90.0%

DC braking time: 0.0 ~ 30.0s; DC braking function does not required waiting time to start to realize quick braking  

Magnetic flux braking

Enabled or disabled during deceleration are optionalthe default setting is enabled

Unique functions

Multi-function M key

The unique multi-function key can be set to frequently used operations: such as JOG, emergency stopswitchover of run command sourceswitchover of parameters display mode, etc. 

Multiple parameters display modes

Basic parameters display mode, fast parameters display modenon−factory setting parameters display mode, last changed 10 parameters display mode

Parameters copy

The standard operation panel can realize the parameters upload, download and display the copy progress. Users can set to forbid overwriting the uploaded parameters

Displayed and hidden parameters group

The customer can select to display or hide the parametergroup by themselves

Dual 485 communication ports

Dual 485 communication ports support Modbus protocol (RTU). The maximum distance is 500 meters

Operation panel

Key type or shuttle type operation panel are optional

Protection level: IP20 as standard, IP54 as option

Common DC bus

All series product support common DC bus

Independent duct

All series product adopts independent duct design and supports the installation of heat-sink outside the cabinet

Universal expansion interface

Universal expansion board equipped with CPU for supporting customers secondary development: physical interface SPI bus, software protocol Modbus

Expansion card

Injection molding machine interface card, PG feedback card, air compressor control cardcommunication adapter card, three phase power supply monitoring card, three phase-sequence detection card, external power rectifying card

Power-On-Self-Test

(POST)

Realizing the POST of internal and peripheral circuits, including motor grounded, abnormal +10V power supply output, analog input and disconnection, etc.

Protection function

Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison levelmotor data identification failure, module(IPM) protection, heat-sink over temperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output short circuit to ground , interruption of power supply when in running status, abnormal input power, output phase loss, abnormal EEPROM protection, abnormal pre-charging contactor detection, temperature sampling disconnection, encoder disconnection, abnormal +10V power supply, abnormal analog input, motor over temperature protection(PTC), abnormal communication, abnormal software version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection, hardware overload protection 

Efficiency

At rated power: 7.5kW and below power class ≥93%

                         45kW and below power class ≥95%

                         55kW and above power class ≥98%

Environment

Operating site

The product should be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The product should be installed in the environment without dust, corrosive gas, combustible gas, oil mist, steam, drip and free from direct sunlight

Ambient temperature

−10 to +40ºC, the product must be de-rated rated output current for the ambient temperature between 40ºC to 50ºC, the rated output current must be de-rated for 1% per 1ºC temperature rise

Humidity

to 95%, no condensing

Altitude

to 2000m, the product must be de-rated rated output current for the altitude above 1000 meters, the rated output current must be de-rated for 1% per 100 meters rise

Vibration

3.5m/s2,2 to 9Hz; 10 m/s2,9 to 200Hz; 15 m/s2,200 to 500Hz

Storage temperature

−40 to +70ºC



Installation Dimension



V5−H−2T0.4G~V5−H−2T2.2G、V5−H−4T7.5G/11L And blow power class




V5−H−4T11G/15L And above power class


Product Appearance, Installation Dimensions, Approximate Weight

Voltage

Model

Appearance, Installation Dimensions(mm)

Weight

(kg)

W

H

D

W1

H1

D1

T1

Hole d

200V

V5−H−2T0.4G

118

190

155

105

173

40.8

3

5.5

1.5

V5−H−2T0.75G

175

60.5

4

2.2

V5−H−2T1.5G

155

40.8

3

1.5

V5−H−2T2.2G

175

60.5

4

2.2

400V

V5−H−4T0.75G/1.5L

118

190

155

105

173

40.8

3

5.5

1.5

V5−H−4T1.5G/2.2L

118

190

175

105

173

60.5

4

5.5

2.6

V5−H−4T2.2G/3.7L

V5−H−4T3.7G/5.5L

V5−H−4T5.5G/7.5L

155

249

185

136

232

69

8

5.5

3

V5−H−4T7.5G/11L

V5−H−4T11G/15L

210

337

200

150

324

88

2

7

8.5

V5−H−4T15G/18.5L

V5−H−4T18.5G/22L

289

440

220

200

425

88

2.5

7

17

V5−H−4T22G/30L

V5−H−4T30G/37L

V5−H−4T37G/45L

319

575

218

220

553

90.5

2.5

10

25

V5−H−4T45G/55L

V5−H−4T55G/75L

404

615

255

270

590

86.5

3.0

10

35

V5−H−4T75G/90L

V5−H−4T90G

V5−H−4T110L

465

745

325

343

715

151.5

3.0

12

55

V5−H−4T110G

V5−H−4T132L

V5−H−4T132G

V5−H−4T160L

540

890

385

370

855

205.5

4.0

14

85

V5−H−4T160G

V5−H−4T185L

V5−H−4T185G

V5−H−4T200L

V5−H−4T200G

V5−H−4T220L

V5−H−4T220G

V5−H−4T250L

700

1010

385

520

977

210

4.0

14

125

V5−H−4T250G

V5−H−4T280L

V5−H−4T280G

V5−H−4T315L

V5−H−4T315G

V5−H−4T355L

810

1358

425

520

1300

210

4.0

14

215

V5−H−4T355G

V5−H−4T400L

400V

V5−H−4T400G

V5−H−4T450L

810

1358

425

520

1300

210

4.0

14

215

V5−H−4T450G

V5−H−4T500L

V5−H−4T500G

V5−H−4T560L


Applications











Representative Industry

Variable frequency drives (VFDs) or AC Drives regulate the rotational force and speed of electric motors by changing the frequency of the input power to the motor. V&T High Performance Universal frequency drive of Shenzhen V&T Technologies Co.,Ltd. are widely used in Printing, Packaging, Petrochemical,Textile, Cable Machinery, Machine Equipment, Food Packaging, Electric Vehicles, Washing Equipment, Plastic Machinery, Metal Products Equipment, Centrifuges and the applications of required open-loop vector etc.




Product Tags 250kW-500kW Speed Controller          3 phase AC Speed Controller          Inverter Drive Solution         

INQUIRY

Contact us for all information about the product


click here to leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.