Total Length and Mounting Option : 50 = 5.0 metre (16.4 feet) system length, panel mount
Agency Approval Option : 0 5 = CSA, ATEX, IECEx approvals
Proximitor Sensor Input : Accepts one non-contacting 3300-series 5 mm, 3300 8 mm or 3300 XL 8 mm Proximity Probe and Extension Cable.
Power : Requires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption, -23 Vdc to -26 Vdc with barriers. Operation at a more positive voltage than -23.5 Vdc can result in reduced linear range.
Supply Sensitivity : Less than 2 mV change in output voltage per volt change in input voltage
Proximitor Sensor Material : A308 aluminum
Connector Material : Gold-plated brass or gold-plated beryllium copper
System Length : 5 or 9 metres (including extension cable) or 1 metre (probe only)
|