Company profile

Xiamen Blushing Sauce E-Commerce Co., Ltd. is a professional service provider in the field of industrial automation parts. We mainly provide PLC modules, DCS cards, ESD system cards, vibration monitoring system cards, turbine control system modules, gas generator components, and we have established close cooperative relations with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and provide equipment and spare parts from different countries and manufacturers to solve your troubles.

All products

ABB TY820K01 3BSE056980R1 10 pcs Temperature Sensor TY820. TY820 is a temperature sensor

10 pcs Temperature Sensor TY820. TY820 is a temperature sensor with a PT 100 element. Can be used with AI835/AI835A and AI843 to measure cold junction Temperature. Email:sean@xmbse.cn

SCHNEIDER LV432693 NSX400N Circuit Breaker

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AI910B (AI4-B) 3KDE175512L9100 ATEX Certification for Zone 2 4 channels Redundancy (Power and Communication)

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI910B Analog Input (AI4-B), input and power supply for 4...20 mA loop powered 2-wire transmitters. Email:sean@xmbse.cn

ABB AI910S (AI4-Ex) 3KDE175511L9100 ATEX Certification for installation in Zone 1 Extended Diagnostic

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI910S Analog Input (AI4-Ex), input and power supply for 4...20 mA loop powered 2-wire transmitters. Email:sean@xmbse.cn

ABB AI930B (AI4H-B) 3KDE175512L9300 AI930B Analog Input (AI4H-B), input and power supply for 4...20 mA loop powered 2-wire transmitters.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI930B Analog Input (AI4H-B), input and power supply for 4...20 mA loop powered 2-wire transmitters. Email:sean@xmbse.cn

ABB AI930N (AI4H) 3KDE175513L9300 Redundancy (Power and Communication) Cyclic HART variables

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. AI930N Analog Input (AI4H), input and power supply for 4...20 mA loop powered 2-wire transmitters. Email:sean@xmbse.cn

ABB AI930S (AI4H-Ex) 3KDE175511L9300 ATEX Certification for Zone 1 Power supply for 4...20 mA loop powered 2-wire transmitters

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI930S Analog Input (AI4H-Ex), input and power supply for 4...20 mA loop powered 2-wire transmitters. Email:sean@xmbse.cn

ABB AI931B (AI4H-B) 3KDE175512L9310 AI931B Analog Input (AI4H-B), passive inputs for 0/4...20 mA.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI931B Analog Input (AI4H-B), passive inputs for 0/4...20 mA. Email:sean@xmbse.cn

ABB AI931N (AI4H) 3KDE175513L9310 AI931N Analog Input (AI4H), passive inputs for 0/4...20 mA.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. AI931N Analog Input (AI4H), passive inputs for 0/4...20 mA. Email:sean@xmbse.cn

ABB PM802F 3BDH000002R1 ▏ABB Base Unit

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AI931S (AI4H-Ex) 3KDE175511L9310 AI931S Analog Input (AI4H-Ex), passive inputs for 0/4...20 mA.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units.S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI931S Analog Input (AI4H-Ex), passive inputs for 0/4...20 mA. Email:sean@xmbse.cn

ABB AI950B (TI4-B) 3KDE175522L9500 AI950B Temperature Input (TI4-B), supporting Pt100, Pt1000and Ni100 in 2-/3-/4- technology. mA.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI950B Temperature Input (TI4-B), supporting Pt100, Pt1000and Ni100 in 2-/3-/4- technology. Thermocouples B, E, J, K, L, N, R, S, T, U, mV. Isolated inputs channel by channel. Email:sean@xmbse.cn

ABB AI950N (TI4) 3KDE175523L9500 Pt 100, Pt 1000, Ni 100, 0...3kOhms in 2/3/4 wire technique

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units.S900 I/O type N. For installation in safe (= non-hazardous) area. AI950N Temperature Input (TI4), supporting Pt100, Pt1000 and Ni100 in 2-/3-/4-technology. Thermocouples B, E, J, K, L, N, R, S, T, U, mV. Isolated inputs channel by channel. Email:sean@xmbse.cn

ABB AI950S (TI4-Ex) 3KDE175521L9500 Pt 100, Pt 1000, Ni 100, 0...3kOhms in 2/3/4 wire technique

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI950S Temperature Input (TI4-Ex), supporting Pt100, Pt1000 and Ni100 in 2-/3-/4-technology. Thermocouples type B, E, J, K, L, N, R, S, T, U, mV. Isolated inputs channel by channel. Email:sean@xmbse.cn

ABB AO910B (AO4-B) 3KDE175532L9100 Output signal 0/4...20 mA for actuators

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO910B Analog Output (AO4-B), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB AO910N (AO4) 3KDE175533L9100 AO910N Analog Output (AO4), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. AO910N Analog Output (AO4), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB AO910S (AO4-Ex) 3KDE175531L9100 AO910S Analog Output (AO4-Ex), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO910S Analog Output (AO4-Ex), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB AO920B (AO4I-B) 3KDE175532L9200 AO920B Analog Output (AO4I-B), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO920B Analog Output (AO4I-B), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB AO920N (AO4I) 3KDE175533L9200 AO920N Analog Output (AO4I), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units.S900 I/O type N. For installation in safe (= non-hazardous) area. AO920N Analog Output (AO4I), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB AO920S (AO4I-Ex) 3KDE175531L9200 AO920S Analog Output (AO4I-Ex), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO920S Analog Output (AO4I-Ex), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB AO930B (AO4H-B) 3KDE175532L9300 AO930B Analog Output (AO4H-B), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO930B Analog Output (AO4H-B), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB AO930N (AO4H) 3KDE175533L9300 AO930N Analog Output (AO4H), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. AO930N Analog Output (AO4H), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

ABB CI920AB (CIPBA-B) 3BDH000691R1 CI920AB Communication Interface V2.1 (CIPBA-B), for Fieldbus protocol PROFIBUS DP-V1 (IEC 61158)

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. CI920AB Communication Interface V2.1 (CIPBA-B), for Fieldbus protocol PROFIBUS DP-V1 (IEC 61158). Use only CI920AB with the same firmware for redundancy for PROFIBUS DP-V1 (observe Release Notes). Email:sean@xmbse.cn

ABB CI920AN (CIPBA) 3BDH000692R1 Line or media redundancy via two coupling modules

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. CI920AN Communication Interface V 2.1 (CIPBA), for Fieldbus protocol PROFIBUS DP-V1 (IEC 61158). Use only CI920AN with the same firmware for redundancy for PROFIBUS DP-V1 (observe Release Notes). Email:sean@xmbse.cn

ABB CI920AS (CIPBA-Ex) 3BDH000690R1 CI920AS Communication Interface V 2.1 (CIPBA-Ex), for Fieldbus protocol PROFIBUS DP-V1 (IEC 61158)

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. CI920AS Communication Interface V 2.1 (CIPBA-Ex), for Fieldbus protocol PROFIBUS DP-V1 (IEC 61158). Use only CI920AS with the same firmware for redundancy for PROFIBUS DP-V1 (observe Release Notes). Email:sean@xmbse.cn

ABB DO910B (D04-B) 3KDE175322L9100 connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. DO910B Digital Output (DO4-B), output for intrinsically safe valves or alarms. Email:sean@xmbse.cn

ABB DO910N (D04) Digital Output Solenoid driver S900 Small Equipment (No External Dimension More Than 50 cm)

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. DO910N Digital Output (DO4), output for intrinsically safe valves or alarms. Email:sean@xmbse.cn

ABB DO910S (DO4-Ex) 3KDE175321L9100 Redundancy (Power and Communication) Hot Configuration in Run

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. DO910S (DO4-Ex), output for Intrinsically safe valves or alarms. Email:sean@xmbse.cn

ABB PM851AK01 The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface.

Reliability and simple fault diagnosis procedures Modularity, allowing for step-by-step expansion IP20 Class protection without the requirement for enclosures The controller can be configured with 800xA control builder The controller has full EMC certification Hardware based on standards for optimum communication connectivity (Ethernet, PROFIBUS DP, etc.) Email:sean@xmbse.cn

ABB PM856AK01 The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface.

Reliability and simple fault diagnosis procedures Modularity, allowing for step-by-step expansion IP20 Class protection without the requirement for enclosures The controller can be configured with 800xA control builder The controller has full EMC certification Hardware based on standards for optimum communication connectivity (Ethernet, PROFIBUS DP, etc.) Email:sean@xmbse.cn

ABB DP910N (FI2) 3KDE175363L9100 S900 I/O type N. For installation in safe (= non-hazardous) area.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. DP910N Frequency Input (FI2), frequency input for dry contacts or proximity switches. Email:sean@xmbse.cn

ABB PM857K01 The base plate of the PM857 controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial por

ISA Secure certified - Read more AC 800M High up to SIL 3 certified using PM857/SM812, PM863/SM812, PM865/SM811 or PM867/SM812 Supports S800 I/O High Integrity (PM857, PM863, PM865, PM866A and PM891) The controller can be configured with 800xA control builder The controller has full EMC certification TÜV Certified SIL 2 and SIL 3 Built-in redundant Ethernet Communication ports Email:sean@xmbse.cn

ABB DP910S (FI2-Ex) 3KDE175361L9100 DP910S Frequency Input (FI2-Ex), frequency input for dry contacts or proximity switches.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. DP910S Frequency Input (FI2-Ex), frequency input for dry contacts or proximity switches. Email:sean@xmbse.cn

ABB PM857K02 The base plate of the PM857 controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial por

ISA Secure certified - Read more AC 800M High up to SIL 3 certified using PM857/SM812, PM863/SM812, PM865/SM811 or PM867/SM812 Supports S800 I/O High Integrity (PM857, PM863, PM865, PM866A and PM891) The controller can be configured with 800xA control builder The controller has full EMC certification TÜV Certified SIL 2 and SIL 3 Built-in redundant Ethernet Communication ports Email:sean@xmbse.cn

ABB DX910B (DIO8-B) 3KDE175312L9100 S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. DX910B Digital Input or Output (DI08-B), input for dry contacts or proximity switches, output for low power intrinsically safe valves. Email:sean@xmbse.cn

Showing 6 to 11 of 11 (6 Pages)

click here to leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.