Ø No Load power consumption<0.5W
Ø Universal AC input range(90~264Vac)
Ø High efficiency, long life and high reliability
Ø Withstand 300VA surge input for 5 sec.
Ø Output protections: OPP/OLP/SCP
Ø Wide operating ambient temp (-20℃~70℃)
Ø All using105℃long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø Suitable for critical applications
Ø 2 years warranty
MODEL
|
ABS-15-5
|
ABS-15-12
|
ABS-15-24
|
OUTPUT
|
DC Output
|
5V
|
12V
|
24V
|
Rated Current
|
3A
|
1.3A
|
0.7A
|
Current Range Note 1
|
0~3A
|
0~1.3A
|
0~0.7A
|
Ripple and Noise
Note 2
|
0~70℃
|
<50mV
|
<120mV
|
<120mV
|
-20℃
|
<150mV
|
<150mV
|
<200mV
|
Voltage ADJ. Range
|
4.75V-5.25V
|
11.4V-12.6V
|
22.8V-25.2V
|
Voltage Accuracy
|
±2.0%
|
±1.0%
|
±1.0%
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
Load Regulation
|
±1.5%
|
±0.5%
|
±0.5%
|
Set-up Time
|
≤2S /115Vac input, Full load) ; ≤1S /230Vac input, Full load)
|
Hold up Time
|
≥10mS(115Vac input, Full load) ; ≥20mS(230Vac input, Full load)
|
Temperature Coefficient
|
±0.03%/℃
|
Overshoot and Undershoot
|
<5.0%
|
INPUT
|
Voltage Range
|
90Vac~264Vac
|
Frequency Range
|
47Hz~63Hz
|
Efficiency ( Typical)
|
≥76%
|
≥80%
|
≥83%
|
AC Current (max.)
|
<0.7 A
2.5A
|
Inrush Current (Typical)
|
﹤65A@230Vac Cold start
|
Leakage Current
|
Input—output:<0.25mA Input—PG:<3.5mA
|
PROTECTION
|
Over Load
|
3.15~4.5A
Hiccup, auto recovery
|
1.36~1.95 A
Hiccup, auto
recovery
|
0.73~1.05 A
Hiccup, auto
recovery
|
Over power
|
15.75~22.5W
Hiccup, Auto recovery
|
16.38~23.4W
Hiccup, auto
recovery
|
17.64~25.2W
Hiccup, auto
recovery
|
Shorted Circuit
|
Long-term mode, auto recovery
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-25℃~70℃; 20%~90%RH No condensing
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
SAFETY
&EMC
Note
3
|
Safety Standards
|
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.
|
Isolation Resistance
|
≥100M ohms
|
EMC Emission
|
Compliance to EN55022 Class
B
|
Harmonic Current
|
Compliance to EN61000-3-2, Class D
|
EMC Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2heavy industry level
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 200,000Hrs (25℃, Full load)
|
Dimension (L*W*H)
|
79×51×28.8mm
|
Packing
|
48PCS/CTN, 10.5KGS, 0.03CBM
|
Cooling method
|
Cooling by free air convection
|
NOTE
|
1.
All parameters NOT specially mentioned are measured at rated input, rated
load and25℃of ambient temperature.
2.
Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF &
10uF parallel capacitor.
3.
The SPS is considered a component which will be installed into final
equipment. The equipment must be re-confirmed that it still meets EMC
directives.
4. Powerld offer accessories for Din-35 rail
bar. Please contact sales staff for details.
|
We are professional manufacturer engaged in the research, development, production, sale and service of Industrial power supply,We sincerely look forward to cooperating with you and creating the future together!