Stepper motors power supply 200W 24V with CCC CE CB certification
Description:
K26B-UP200S24 is 100-240vac input voltage and open frame 24VDC single output switching power supply with PFC function, high quanlity,it is used in electronic LED stage lights.
Features:
1, 200W high efficiency 24V stepper motors power supply;
2, Wide range of AC input voltage,24V 200W single output power supply open frame;
3, Over load, short circuit protection,over-temperature protection;
4, 200W 24V small size power supply built-in active PFC function.
Parameter
|
Item No.
|
K26B-UP200S12
|
K26B-UP200S24
|
K26B-UP200S36
|
K26B-UP200S48
|
Output
|
Output Voltage
|
+12V
|
+24V
|
+36V
|
+48V
|
Rated Current
|
16.7A
|
8.3A
|
5.6A
|
4.2A
|
Current Range
|
0-16.7A
|
0-8.3A
|
0-5.6A
|
0-4.2A
|
Rated Power
|
200.4W
|
204W
|
201.6W
|
201.6W
|
Ripple & Noise
|
200mVp-p
|
240mVp-p
|
360mVp-p
|
480mVp-p
|
Adjustable Output Range
|
±10%
|
Output Accuracy
|
±1%
|
Line Regulation
|
±0.5%
|
Load Regulation
|
±0.5%
|
Set up,Rise,Keep up time
|
500ms, 50ms, 20ms
|
Input
|
Input Voltage Range
|
90-264V AC
|
Input Current
|
1.2A@220V AC
|
Input Frequency
|
47-63Hz
|
Power Factor
|
>0.95@110VAC; >0.99@220VAC
|
Efficiency @230Vac
|
>88%
|
>90%
|
>90%
|
>92%
|
Inrush Current
|
Cold start 15A@115V,30A@230V
|
Leakage Current
|
<0.75mA@240V
|
Protection
|
Over Load Protection
|
110~200% Hiccup automatic protection
|
Short Circuit Protection
|
---
|
Over Temp., protection
|
>105 degree,receovers automatically after the temp. goes down.
|
Environment
|
Working Temp.,Humidity
|
-20~50℃,10~90% RH,No condensation
|
Storage Temp.,Humidity
|
-20~85℃,10~95% RH
|
Temp.,Drift
|
±0.03%/℃(0~50℃)
|
Vibration
|
10~500Hz, 2G 10min /1cycle, PERIOD FOR 60min EACH AXES
|
Safety&EMC Standards
|
Safety Standards
|
GB4943,EN60950
|
Withstand Voltage
|
I/P-O/P:3KV; I/P-FG:1.5KV;O/P-FG:0.5KV DC 1min
|
Insulation Resistance
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
|
EMC Standards
|
GB9254 EN55022 CLASS B,EN6100-3-2
|
Others
|
Dimension
|
148*60*35mm(L*W*H)
|
Weight
|
0.4kg
|
Notes
|
1.All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured.
|
Product picture: