600w dual 32v 12v switching power supplies
Description:
This K18C-UP600D model is suitable for use in telecommunications, networking, test and measurement, IT applications, general electronics, low profile systems, automation, POS, motor based machinery and non patient contact medical equipment.
Features:
1, 600W high efficiency 32v 12V dual power supplies;
2, K18C-UP600D32+12 model have small size, high efficiency;
3, International universal full voltage input;
4, 600W DUAL 32V 12V built-in active PFC function;
5, Built-in filter, low noise, high reliability;
6, Overload, short circuit, under voltage, over voltage, over temperature protections and etc.
Parameter
|
Item NO
|
K18C-UP600D32+12
|
Output
|
Output voltage
|
V1
|
V2
|
|
|
+32VDC
|
+12VDC
|
|
Rated current
|
18.5A
|
2A
|
|
Rated power
|
592W
|
24W
|
|
Ripple & noise
|
350mVp-p
|
200mVp-p
|
|
Voltage adjustable range
|
30-34V
|
/
|
|
Output accuracy
|
±1%
|
±3%
|
|
Line regulation
|
±0.5%
|
±0.5%
|
|
Load regulation
|
±1 %
|
±3%
|
|
Cross adjustment rate
|
±3 %
|
±17 %
|
|
Set up,rise,keep up time
|
300ms,20ms,12ms
|
Input
|
Input voltage range
|
100V~240V AC
|
|
Input current
|
3.8A/230Vac 7.6A@115Vac
|
|
Frequency range
|
50~60Hz`
|
|
Efficiency@230Vac
|
92%
|
|
Power factor
|
PF>0.98/115V orPF>0.95/230V
|
|
Inrush current
|
Cold start 60A/230Vac
|
|
Leakage current
|
<0.5mA@240V
|
Protection
|
Overload protection
|
105~150% Hiccup protection, automatic recovery。
|
|
Short circuit protection
|
Deadlocked protection, need to be restored after restart.
|
|
Output over-voltage protection
|
>120% off, locked protection, need to restart after recovery.
|
|
Over-temperature protection
|
TS1 position > 105°C will beprotected, automatic recovery.
|
Function
|
Fan supply
|
/
|
Environment
|
Work temperature,humidity
|
-20~70℃,10~90% RH,No condensation
|
|
Storage temperature humidity
|
-20~85℃,10~95% RH
|
|
Temperature drift
|
±0.03%/℃(0~50℃)
|
|
Vibration
|
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
|
Safety & EMC standards
|
Safety standards
|
GB4943 EN60950
|
|
Withstand voltage
|
I/P-O/P:3KV; I/P-FG:1.8KV;O/P-FG:0.6KV AC 1min.
|
|
Insulation resistance
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
|
|
EMC standards
|
/
|
Others
|
MTBF
|
>50K hrs
|
|
Dimension
|
168*82*40.
|
|
Weight
|
0.8 KG
|
Note
|
1. All parameters 230VAC input, rated load, ambient temperature 25℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured..
|
Product picture: