LED screen power supply 50W with CE certification
Description:
K02-U50S5 is 100-240vac input voltage and DC5V 10A output power supply with small size, high quanlity,it is used in the LED screen,electronic LED stage lights,robot and other industrial equipments.
Features:
1, high efficiency 5V 10A LED screen power supply;
2, Wide range of AC input voltage,5V 10A output;
3, Over load, short circuit protection,over-temperature protection;
4, 50W 5V small size power supply built-in active PFC function.
Parameter
|
Item No.
|
K02-U50S5
|
K02-U50S12
|
K02-U50S24
|
K02-U50S36
|
Output
|
Output Voltage
|
+5V
|
+12V
|
+24V
|
+36V
|
Rated Current
|
10A
|
4.17A
|
2.08A
|
1.39A
|
Current Range
|
0-10A
|
0-4.17A
|
0-2.08A
|
0-1.39A
|
Rated Power
|
50W
|
50W
|
50W
|
50W
|
Ripple & Noise
|
80mVp-p
|
120mVp-p
|
240mVp-p
|
360mVp-p
|
Adjustable Output Range
|
±10%
|
Output Accuracy
|
±1%
|
Line Regulation
|
±0.5%
|
Load Regulation
|
±0.5%
|
Set up,Rise,Keep up time
|
500ms, 50ms, 20ms
|
Input
|
Input Voltage Range
|
90-264V AC
|
Input Current
|
1A@115V AC,0.5A@230VAC
|
Input Frequency
|
47-63Hz
|
Power Factor
|
>0.5@110VAC; >0.5@220VAC
|
Efficiency @230Vac
|
81%
|
84%
|
85%
|
86%
|
Inrush Current
|
Cold start 10A@115V,20A@230V
|
Leakage Current
|
<0.5mA@240V
|
Protection
|
Over Load Protection
|
110~200% Hiccup automatic protection
|
Short Circuit Protection
|
---
|
Over Temp., protection
|
>105 degree,receovers automatically after the temp. goes down.
|
Environment
|
Working Temp.,Humidity
|
-20~50℃,10~90% RH,No condensation
|
Storage Temp.,Humidity
|
-20~85℃,10~95% RH
|
Temp.,Drift
|
±0.03%/℃(0~50℃)
|
Vibration
|
10~500Hz, 2G 10min /1cycle, PERIOD FOR 60min EACH AXES
|
Safety&EMC Standards
|
Safety Standards
|
GB4943,EN60950
|
Withstand Voltage
|
I/P-O/P:3KV; I/P-FG:1.5KV;O/P-FG:0.5KV DC 1min
|
Insulation Resistance
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
|
EMC Standards
|
EN55032 CLASS B
|
Others
|
Dimension
|
99*83*30mm(L*W*H)
|
Weight
|
0.4kg
|
Notes
|
1.All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured.
|
Product picture: