Desktop BMS Tester with Computer
FEATURE
The integrated test equipment for finished batteries is a fast and accurate equipment for testing the performance of finished batteries. The main test items are: open circuit voltage, AC internal resistance, discharge test, discharge overcurrent test, short circuit protection test, charging test and charging protection test. The system uses 32-bit ARM processor and 16-bit AD converter for voltage and current. Compared with similar devices, the system has fast test speed, high test precision and supports multiple devices to operate at the same time. Widely used in automotive electronics, aerospace, ships, solar energy storage, electric bicycles, electric motorcycles, backup power batteries, communications power and other power battery production and scientific research and experimental testing. We insist on making premium Battery Discharge Tester for you!
SPECIFICATION
Input Power
|
AC220V±10%/50HZ
|
Open Circuit Voltage
|
Testing Range
|
0-100V
|
|
Resolution Ratio
|
±2mV
|
Current
|
Charging Range
|
0.05-15A
|
|
Resolution Ratio
|
±1mA
|
|
Discharge Range
|
0.05-120A
|
|
Resolution Ratio
|
±1mA
|
|
Accuracy
|
± 0.2% of reading ± 0.2% of range
|
Internal Resistance
|
Resolution Ratio
|
±1mΩ
|
Short Circuit Protection
|
Time
|
0-999us
|
|
Resolution Ratio
|
±0.1uS
|
Middle Machine Type
|
1.1 series
|
|
Voltage and Current Testing Sample
|
4-wire connecting
|
Data Management
|
MySQL Database
|
Communication Means
|
TCP/IP Protocol
|
Data Output
|
EXCEL,TXT
|
Communication Interface
|
Ethernet Port
|
Size
|
850x700x920mm
|
Test Items
1. Open circuit voltage: test the voltage at both ends of the open circuit positive and negative electrodes of the battery.
2. Ac internal resistance: test the resistance values at both ends of the battery discharge circuit.
3. Discharge test: test the battery's carrying capacity, and make the battery discharge for a certain time to check the voltage drop.
4. Discharge overcurrent test: test the battery's high-current discharge protection function, and the high-current discharge of the battery triggers the discharge overcurrent protection function of the battery's protection plate.
5. Short-circuit protection: test battery positive and negative pole short battery cut off protection time (microsecond level).
6. Charging test: test the continuous charging function of the battery, and test whether the battery charging function is good.
7. Charging overcurrent test: test the charging protection function of the battery with high current, which triggers the charging current protection function of the battery protection plate.