dual 5V 12V 10A switching power supply
Description:
Dual 5V 12V 10A switching power supply is suitable for use in telecommunications, networking, test and measurement, IT applications, general electronics, low profile systems, automation, POS, motor based machinery and non patient contact medical equipment.
Features:
1, Small size high power 5V power supplies;
2, 12V power supplies with wide range of AC input voltage;
3, 5V 12V power supplies with Overload, short circuit, over voltage protections.
Parameter
|
Item No.
|
K10L-S300D5+12
|
CH1
|
CH2
|
Output
|
Output Voltage
|
+5V
|
+12V
|
Rated Current
|
10A
|
10A
|
Current Range
|
0.5-10A
|
0.4-10A
|
Rated power
|
300W
|
Ripple
|
100mVp-p
|
100mVp-p
|
Adjustable output range
|
±10%
|
------
|
Output Accuracy
|
±5%
|
±1%
|
Line Regulation
|
±1%
|
±1%
|
Load Regulation
|
±5%
|
±1%
|
Set up,Rise,Keep up time
|
300ms,50ms,20ms
|
Input
|
Input Voltage range
|
88~132V,176~264V AC
|
Input current
|
6A/115V,3A/230V AC
|
Input frequency
|
47~63Hz
|
Efficiency
|
>84% @ 220V AC
|
Inrush current
|
COLD START 40A/230V
|
Leakage Current
|
<0.5mA/240VAC
|
Protection
|
Over load protection
|
105~150%
|
Output over voltage
|
------
|
Environment
|
Working Temp.,Humidity
|
-20~50℃,10~90% RH,No condensation
|
Storage Temp.,Humidity
|
-20~85℃,10~95% RH
|
Temp.,Drift
|
±0.03%/℃(0~50℃)
|
Vibration
|
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
|
Safety&EMC Standards
|
Safety standards
|
GB4943
|
Pressure
|
I/P-O/P:3KV;I/P-FG:1.5KV;O/P-FG:0.5KV AC 1min.
|
Insulation resistance
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
|
EMC standards
|
EN55032 CLASSA
|
Others
|
Dimension
|
215×110×50mm
|
Weight
|
1Kg
|
Notes
|
1. All parameters220VACinput, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. RippleTest:30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 20% to 100% load change measured, other load is fixed at 60% of the load;
|
Product picture: