To activate V/f Control with PG feedback:
1. Set the drive to V/f Control (A1-02 = 0).
2. Connect the motor speed pulse signal to the pulse input RP, set H6-01 = 3, and set the pulse signal frequency that is equal
to the maximum speed to H6-02 (pulse input scaling). Make sure the pulse input bias (H6-04) is 0% and the gain (H6-03)
is 100%.
3. Decide the signal used for detecting the direction. If a digital input is used set H1-oo = 7E.
4. Use the ASR gain and integral time parameters described below for adjusting the ASR responsiveness.
Note: 1. C5 parameters will appear only when using V/f Control (A1-02 = 0) and when the pulse input RP function is set for PG feedback in V/
f Control (H6-01 = 3).
2. V/f Control with PG feedback can be used for motor 1 only