Dual Power Supply DC12V 24V 200W SMPS
Description:
K26B-UP200D12+24 DC12V/12.5A 24V/2A power supply 200W is 100-240vac input voltage dual output switching power supply with PFC function, high quanlity,it is widely used to the stage lights,power amplifer and POE switch.
Features:
1, 200W high efficiency switching power supply;
2, Wide range of AC input voltage,200W dual output power supply open frame;
3, Over load, short circuit protection,over-temperature protection;
4, 200W small size power supply built-in active PFC function.
Parameter
|
Item NO
|
K26B-UP200D12+24
|
Output
|
Output Voltage
|
CH1:+12VDC CH2:+24VDC
|
Rated Current
|
CH1:12.5A CH2:2A
|
Current Range
|
CH1:0-16.7A CH2:0-3A
|
Rated Power
|
198W
|
Ripple & Noise
|
CH1:200mVp-p CH2:240mVP-P
|
Adjustable Output Range
|
±10%
|
Output Accuracy
|
CH1:±1% CH2:+/-5%
|
Line Regulation
|
CH1:±0.5% CH2:+/-2%
|
Load Regulation
|
CH1:±0.5% CH2:+/-3%
|
Set up,Rise,Keep up time
|
500ms, 50ms, 20ms
|
Input
|
Input Voltage Range
|
90-264V AC
|
Input Current
|
2.5A/115V,1.2A/230V
|
Input Frequency
|
47~63Hz
|
Efficiency
|
>89%@230V,>85%@115V
|
Power Factor
|
>0.9
|
Inrush Current
|
Cool start 20A/230V
|
Leakage Current
|
<0.5mA@240V
|
Protection
|
Over Load Protection
|
105~180%,Hiccup protection,automatic recovery
|
Short Circuit Protection
|
Hiccup,automatic recovery
|
Output over-voltage protection
|
........
|
Over-temperature protection
|
>105 ℃ protection, automatic recovery
|
Environment
|
Working Temp.,Humidity
|
-20~40℃,10~90% RH,No condensation
|
Storage Temp.,Humidity
|
-20~85℃,10~95% RH
|
Temp.,Drift
|
±0.03%/℃(0~50℃)
|
Vibration
|
10~500Hz, 2G 10min /1cycle,PERIOD FOR 60min EACH AXES
|
Safety&EMC Standards
|
Safety Standards
|
GB4943 EN60950
|
Withstand Voltage
|
I/P-O/P:1.5KV;I/P-FG:1.8KV;O/P-FG:0.5KV AC
|
Insulation Resistance
|
I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms
|
EMC Standards
|
GB9254 EN55022 CLASS B EN61000-3-2
|
Others
|
Dimension
|
148*60*38mm(L*W*H)
|
Weight
|
0.4kg
|
MTBF
|
>50000Hrs
|
Fan Supply
|
---
|
Notes
|
1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured.
|
Product picture: