Guangzhou zhilitong Electromechanical Co.,Ltd manufacture Safety Test Equipment,IEC Accredited Test Machine Manufacturer,UL Precision Testing Machine. We will provide you with consistently high quality products.

All products

Microwave Oven Door Endurance Tester

ZLT-WM1. To determine the endurance of the door system, including the hinges, microwave seals and other associated parts, shall be constructed to withstand wear that may be expected in normal use, according to the IEC60335-2-25 clause 18.

Electric Iron Drop Tester

ZLT-IF1. To determine the mechanical strength of electric irons by repeated drop onto a steel plate according to IEC60335-2-3 clause 21.101.

Load for Testing Rotating Spits

ZLT-LR. This load confirms to the IEC60335-2-9 figure 102, mass approximately 4.5kg.

Test Vessel

ZLT-VL6. This Test Vessel confirms to the IEC 60335-2-6 clause 21.102,

Test Corner

ZLT-BDK. To measure the temperatures, according to IEC 60335-1 clause 11.2 and 11.3, EN61010 clause 9.2,VDE 0551 Part 1,VDE 0700 Part 1.

Copper Disks

Made of copper or brass,15 mm in diameter and 1 mm thick,accordance with IEC 60335-1 clause 11.3.

Appliance Stability Test Equipment

ZLT-WD3. Table diameter: 1000mm, to determine the stability of electric appliances ,in accordance with IEC60065 clause 19.1, IEC60335-1 clause 20.1, IEC60601-1 clause 24.1, IEC 60950 clause 4.1.1

Appliance Stability Tester

ZLT-WD2. Table diameter: 800mm ,to determine the stability of electric appliances ,in accordance with IEC60065 clause 19.1, IEC60335-1 clause 20.1, IEC60601-1 clause 24.1, IEC 60950 clause 4.1.1

Scratch Pin Probe

ZLT-GC1A ,according to IEC60950 figure 2K and clause 2.10.8.4,IEC60335-1 clause 21.2.

IEC 60529 IPX3 IPX4 Spray Nozzle

ZLT-JL1. For checking the protection against ingress of water to prove the degrees of protection with the second characteristic numerals 3 “Protected against Spraying Water” and 4 “Protected against Splashing Water”, in accordance with IEC60529 figure 5, IEC60335 clause 15.1.1, IEC60598.

IEC 60529 IPX5 & IPX6 Water Jet Nozzle

ZLT-JL2. For checking the protection against ingress of water to prove the degrees of protection with the second characteristic numerals 5 “Protected against water jets” or 6 “Protected against powerful water jets”, in accordance with IEC60529 figure 6, IEC60335-1 clause 15.1.1, EN60950, IEC60598 figure 8.

IEC 60529 Drip Box

ZLT-DB. For checking the protection against water to prove the degrees of protection with the second characteristic numerals 1 “Protection against water drops” and 2 “Protection of a specimen in a position of tilt against water drops” According to IEC60529 Fig 3 Table 8, IEC60335-1 clause 15.1.1, IEC60947-1 Annex C.14.1, IEC60598-1 clause 9.2.3

IEC 60529 Oscillating Tubes Device

ZLT-DP. For checking the protection against water with spray nozzle of 0,4 mm bore are used to prove the degrees of protection for the second characteristic numerals 3 and 4 “Protection against Spraying Water” resp. “Protection against splashing Water”. According to IEC60529 figure 4, IEC60598 clause 9.2.5, IEC60947.

IEC 60529 Turntable Test Device

ZLT-TD. To carry the specimens when determining the protection against water, according to IEC60529 figure 4, IEC 60335-1 clause 15.1.1, IEC60598 clause 9.2.4 and 9.2.5.

IEC 60529 IPX Water Test Whole System

ZLT-IPX1-6. For checking the protection against ingress of water to prove the degrees of protection with the second characteristic numerals 1 to 6, in according to IEC60529 IPX1-6.

Creepage Distances Gauges

ZLT-CK. For gauging the creepage and clearance distances in dead state between parts under voltage in the operating conditions as well as between touchable metal pieces and parts under voltage in the operating conditions. e. g. in installation material, switchgears, plugs, socket-outlets and electric appliances

Mandrel Test Apparatus

ZLT-BM1. The Mandrel is used to test non-separable thin sheet material. Constructional requirements with regard to Protection against Electric Shock for IEC61558-1 Figure6, IEC60065 Figure14 16 and IEC60950 Annex AA.

Dielectric Strength Test Instrument

ZLT-KQ1. To test the surge strength according to IEC60065 figure 6 and UL1310 clause 40.2,

75 and 20 Pounds Force Test Instrument

ZLT-F75P. For resistance to crushing on direct plug-in units, according to UL1310-2005 clause 46.5.1,UL1310-2005 clause 46.4.2.

Test Chain

ZLT-P. To check the short-circuit protection,according to IEC50598 clause 4.26.3.

Expanded Metal Spacer

ZLT-S1. according to IEC 60598 clause 9.2, to tests for ingress of dust, solid objects and moisture,

Crush Test Flat Surface

According to IEC 62368:4.8.4.6, a flat surface measuring approximately 100 mm by 250 mm for crush test.

Dust Test Chamber

In accordance with IEC60529/2001 figure 2 and IEC 60598 etc,

Spring Operated Impact Hammer

ZLT-CJ1, Single Model ,test the mechanical integrity of product enclosures, according to IEC60068-2-75 Ehb, EN, UL, CSA and other international Standards

Vitreous and Porcelain Enamels Pistol Impact Test Device

ZLT-CJ6, It is for vitreous and porcelain enamels Determination of the pistol test, and accordance with ISO4532.

Spring Hammer Calibration Device

ZLT-CD, for testing and calibrating spring operated impact hammer, in accordance with IEC60068-2-75/1997-08 Annex B, Figure B.1 to B.4

Vertical Hammer Test Device

ZLT-SZ1, Conforms to IEC60068-2-75 Test Ehc, The hammer consists basically of a striking element which falls freely from rest through a vertical height

Pendulum Impact Test Apparatus

ZLT-BC1, To test the mechanical strength with impact element according to IEC60068-2-75 Tab. 1 and Tab.2, similar Annex D.

Steel Ball Dropping Test Device

For testing the mechanical strength and the impact strength by pendulum test and by drop test, according to IEC60598 Fig 21,IEC60950 clause 4.2.5 and figure 4A

Striking Element Test Device

ZLT-SE, conform to IEC60068-2-75 table 1 and table 2.

Calibration Device Adjustment Arrangement Tester

For testing and gauging the scale of spring hammer calibration devices in accordance with IEC60068-2-75/1997-08 Annex B, Figure B.5 and B.6

Impact Strength Steel Ball

ZLT-GQ, To determine the mechanical strength and the impact strength by pendulum test resp, by drop test. Material: steel ball hardened.

Calibration Device for Spring Hammer

ZLT-CD2, For testing and calibrating spring-operated impact hammer, in accordance with IEC60068-2-75/1997-08 Annex B, Figure B.1 to B.4 with scale for impact energies from 0.2J to 1.2J.

5J Spring Impact Hammer Lab Tester

ZLT-CJ5, Impact Energy 5J ,test the mechanical integrity of product enclosures, according to IEC60068-2-75 Ehb, EN, UL, CSA and other international Standards

IEC60068-2-75 Spring Impact Hammer

ZLT-CJ2, 2J Impact Energy,test the mechanical integrity of product enclosures, according to IEC60068-2-75 Ehb, EN, UL, CSA and other international Standards

F22.50 Spring Hammer Impact Testing

ZLT-CJ3, Universal model ,test the mechanical integrity of product enclosures, according to IEC60068-2-75 Ehb, EN, UL, CSA and other international Standards

BS1363 Gauges

No brief introduction

Copper Block

ZLT-JH, Copper Block conform to IEC 60695

Showing 4 to 5 of 5 (4 Pages)

click here to leave a message

leave a message