800w dual 48v 24v switching power supplies
Description:
This K18C-UP800D series is a highly efficient and reliable dual output enclosed power supply, with a high operating temperature of -20~+60°C and built-in DC fan for forced cooling. Overload, short circuit and over voltage protection with hiccup mode(recovering automatically after fault condition is removed).
Features:
1, 800W high efficiency 48v 24V dual power supplies;
2, K18C-UP800D48+24F model have small size, high efficiency;
3, International universal full voltage input;
4, 800W DUAL 48V 24V built-in active PFC function;
5, Built-in filter, low noise, high reliability;
6, Overload, short circuit, under voltage, over voltage, over temperature protections and etc.
Parameter
|
Item NO
|
K18C-UP800D48+24F
|
Output
|
Output voltage
|
V1
|
V2
|
+48VDC
|
+24VDC
|
Rated current
|
16A
|
1.5A
|
Rated power
|
768W
|
36W
|
Ripple & noise
|
550mVp-p
|
300mVp-p
|
Voltage adjustable range
|
46-51V
|
/
|
Output accuracy
|
±2%
|
±2%
|
Line regulation
|
±0.5%
|
±0.5%
|
Load regulation
|
±1 %
|
±1%
|
Cross adjustment rate
|
+4% /-3%
|
+6% /-20%
|
Set up,rise,keep up time
|
300ms,20ms,12ms
|
Input
|
Input voltage range
|
100V~240V AC
|
Input current
|
3.8A/230Vac 7.6A@115Vac
|
Frequency range
|
50~60Hz`
|
Efficiency@230Vac
|
92%
|
Power factor
|
PF>0.98/115V orPF>0.95/230V
|
Inrush current
|
Cold start60A/230Vac
|
Leakage current
|
<0.5mA@240V
|
Protection
|
Overload protection
|
105~150% Hiccup protection, automatic recovery.
|
Short circuit protection
|
Deadlock protection, need to be restored after restart.
|
Output over-voltage protection
|
>120% off, locked protection, need to restart after recovery.
|
Over-temperature protection
|
TS1 position>105℃ it will be protection, then automatic recovery
|
Function
|
Fan supply
|
12V@0.3A for driving fan,tolerance±15%
|
Environment
|
Work temperature,humidity
|
-20~60℃,10~90% RH,No condensation
|
Storage temperature humidity
|
-20~85℃,10~95% RH
|
Temperature drift
|
±0.03%/℃(0~50℃)
|
Vibration
|
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
|
Safety & EMC standards
|
Safety standards
|
GB4943 EN60950-1
|
Withstand voltage
|
I/P-O/P:3KV; I/P-FG:1.8KV;O/P-FG:0.6KV AC 1min.
|
Insulation resistace
|
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
|
EMC standards
|
/
|
Others
|
MTBF
|
>50K hrs ,MIL-HDBK-217F(25℃)
|
Dimension
|
168*82*60mm(L*W*H)
|
Weight
|
0.8 KG
|
Note
|
1. All parameters 230VAC input, rated load, ambient temperature 25℃, measured under conditions of 70% humidity;
2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;
3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;
4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;
5. Load regulation: the measured output load from 0 to 100% load change measured.
|
Product picture: