Product Item:Home use EECP machine Natural Bypass for heart failure
Omay EECP OM-A Features:
1.Compressor adopted is Gardner Denver imported from Germany,stable and durable.with a lifetime more than 50,000hours.
2.Customized valves special for EECP machine,quick reponse,low temperature and low working noise,lifetime more than 25,000hours.
3.The deflation and inflation time can be adjustable based on different patients.
4.With customer managerment system,can save and print out each patients data.
5. With"demostrate function",will automatically check whether all systems are properly working before doing treatment for patients.
6.Real-time ECG and SpO2 monitor function during treatment,showing the D/S ratio,intuitive observation of treatment effect.
7.It adopts scientific designed system to reduce noise and heat.
8.High efficiency cuffs for energy-saving:low pressure can generate high treatment effect
9.Stable and durable industrial computer adopted
10.Stable software system:Embedded software system,virus can’t attack.
11.The angle of the backrest can be adjusted on the basis of patient's physiological situation.
12.Omay EECP: got CE,ISO13485 and SFDA.
Omay EECP specifications:
1.All the control in the therapeutic process is executed by the computer(automatic therapeutic machine), which simplify the operating process.
2.The patients’ ECG and paulse signal are processed by special module. It uses the wiring installation designed for EMI, with excellent circuit performance, high stability, strong capability of anti-interference.
3.High-quality parts and components are used in this EECP machine ,such as solenoid valve and air-compressor, which ensures the reliability of the whole device.
4.It uses LCD, which is harmless to the operators. Besides, the whole display area can not only show patient’s name but also real-time show ECG waveform, pulse,blood oxygen saturation,treatment pressure,and can freeze down and save the whole screen for observation without affecting the treatment process.
5.While doing EECP treatment,Omay EECP machine can automatically measure and calculate the peak and area ratio of diastole wave and systole wave, and can real-time display to help evaluate, analyze and summary the effect of the treatment.
6.It has a variety of auto-safety protection. When the heart rate of patients grow too fast or slow, the pulsation is too early, or the exhaust is too late due to the inappropriate regulation, it can adopt protective measure to prevent the patients from being hurt.
7.The connection of cuffs and bed relies on the poison-free, wear-resistance tube and non-toxic non-metallic joints. It is simple and fast to install and uninstall the tube and cuff, which is convenient for the operator installation and maintance.
8.The inside of EECP bed use the shakeproof and noisedamping materials. It runs smoothly and quietly.
9.Three different sizes of Cuffs for Calves, lower and upper thighs.
10.Treatment Timer is provided for setting the treatment session and the device stops automatically on the expiry of the “set” time.
Technical Parameter:
ECG Amplifier
|
Input impedance: >2MΩ
Common-mode rejection ratio: >80dB
Bandwidth: 1-20 Hz on display
|
SpO2 Oxygen Saturation
|
Oxygen saturation range: 0 to 100%
|
Accuracy SpO2 (±1 Saturation Deviation)
|
60-100% ± 2 digits for adults using the Finger Clip Sensor
60-100% ± 3 digits for adults using Flex or Reflectance Sensor
60-100% ± 4 digits using Ear Clip Sensor
|
Triggering Method
|
External trigger: R-wave of patient ECG
External trigger ratio: 1:1 or 1:2
ECG triggers range: 35-125 ± 1 bpm
|
Filter Technique
|
Low-pass digital filter eliminates 50/60Hz and high-frequency interference
|
Treatment Pressure Range
|
Adjust from 5-350 mm Hg
|
Cuffs
|
One Set---Calves, lower thighs, and upper thigh/buttocks
|
Treatment Session Timer
|
System automatically stops when set time expires.
|
System Protection
|
Three circuit breakers -Mains and Compressor, and an emergency stop.
|
Electrical Performance
|
Power Requirements:
220V±22V AC, 50/60Hz, 1350W
|
System Dimension
|
Dimension: 2000mm×760mm×600mm
Net Weight: 220 kg
|
Operating Environment
|
Temperature 14 to 104 (-10°C to 40°C )
Relative Humidity <80% (no condensation)
Atmospheric Pressure 700 to 1060 hPa
Atmospheric Free of corrosives gas
|
Transport and Storage Environment
|
Temperature 14 to 140 (-10 °C to 60°C)
Relative Humidity 30 to 85% (no condensation)
Atmospheric Pressure:500 to 1060 hPa
Atmospheric Free of corrosive gas
|