1000W single output switching power supply 48V
Description:
Features:
1, 1000W 48V single output power supply built-in high efficiency;
2, 48V 1000W single output power supply have short circuit, overload, overvoltage and over temperature protection;
3, 48V 21A single output power supply including filters, low output noise;
4,This 1000w smps power supply with full range AC input voltage.
Specification |
||||||||
Item NO. |
K19H-UP1000S12 |
K19H-UP1000S24 |
K19H-UP1000S36 |
K19H-UP1000S48 |
||||
Output |
Output Voltage |
+12V |
+24V |
+36V |
+48V |
|||
Rated Current |
80A |
42A |
28A |
21A |
||||
Current Range |
0-80A |
0-42A |
0-28A |
0-21A |
||||
Rated power |
960W |
1008W |
1008W |
1008W |
||||
Ripple |
240mVp-p |
240mVp-p |
360mVp-p |
480mVp-p |
||||
Adjustable output range |
±5% |
|||||||
Output Accuracy |
±2% |
|||||||
Line Regulation |
±0.5% |
|||||||
Load Regulation |
±1% |
|||||||
Set up,Rise,Keep up time |
1000ms, 30ms, 10ms/115VAC 500ms, 30ms,20ms/230VAC |
|||||||
Input |
Input Voltage range |
88~264V AC |
||||||
Input current |
12A/115V 6A/230V |
|||||||
Input frequency |
47~63Hz |
|||||||
Efficiency |
90% |
92% |
92% |
93% |
||||
Inrush current |
40A@230V |
|||||||
Leakage Current |
<3.5mA@240V |
|||||||
Power Factor |
>0.9@220V,>0.95@110V |
|||||||
Protection |
Over load |
105~150% protection,automic recovery. |
||||||
Short circuit |
Automic recovery |
|||||||
Output over-voltage |
16~18V |
30-33V |
40-43V |
56-60V |
||||
Over temperature |
The cover temperature>105℃,the output shut up,later automic recovery. |
|||||||
Others |
|
With additional12V0.5A for cooling. |
||||||
Environment |
Working Temp.,Humidity |
-20~+60℃,10~90% RH,no consideration. |
||||||
Storage Temp.,Humidity |
-40~85℃,10~95% RH |
|||||||
Temp.,Drift |
±0.03%/℃(0~50℃) |
|||||||
Vibration |
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES |
|||||||
Safety&EMCStandards |
Safety standards |
GB4943 |
||||||
Pressure |
I/P-O/P,I/P-FG:1.5KV;O/P-FG:0.5KV DC 1min. |
|||||||
Insulation resistance |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
|||||||
EMC standards |
EN55022 CLASS A,EN61000-3-2 |
|||||||
Others |
Dimension |
203*82*63mm doesn’t including the terminals length. |
||||||
Weight |
1.5Kg |
|||||||
Note |
1. All parameters are measured at 230 VAC input, rated load, ambient temperature 25 ° C, humidity 70% 2. Accuracy: including setting error, line regulation, load regulation rate; 3. Ripple test: 30cm long wire with the power and load, load and 0.1u and 47u capacitance to 20MHz oscilloscope measured at the load side; 4. Line regulation: the rated load conditions, the input voltage changes from low to high measured; 5. Load regulation: Measured output is measured from 0 load to 100% load change. |
Product picture: