This board can support E, J, K, S, and T standard thermocouples as well as mV inputs with a span of -8 to 45 mV.
|
|
|
IS220PGENH1AE data table
|
offers a maximum software error/conformity error of .25 degrees Fahrenheit. Common mode voltage is +/- 5 volts with AC common-mode rejection of 100dB @50/60Hz.
|
|
E, J, K, S, and T thermocouples can be either grounded or ungrounded and can be located up to 984 feet from the turbine I/O panel.
|
|
Common mode rejection includes filtering for both hardware and software.
|
|