CT112M-2T-0.7~2.2G
|
Input specification
|
Maximum Input PV Voltage
(PV Open-Circuit Voltage)
|
450VDC
|
|
320~370VDC(Vmp)
|
|
388~450VDC (VOC)
|
Input specification (Grid or backup generator input)
|
Input voltage
|
1PH 220V(-15%~30%)
|
Output specification
|
Rated output voltage
|
3PH 220V
|
Output frequency
|
0~500.00Hz(default: 0~50.00Hz)
|
Fault protection
|
Built-in Protection
|
Protection of light load, over-current, over-voltage, output phase-lose, under-load, under-voltage, short circuit, overheating, water pump run dry etc.
|
CT112M-4T-0.7~4G
|
Input specification (PV Input)
|
Maximum Input DC Voltage
(PV Open-circuit Voltage)
|
780VDC
|
Recommended MPPT Voltage Range
|
540~630VDC (Vmp)
|
Recommended Input Operation Voltage
|
670~780VDC (VOC)
|
Input specification (Grid or backup generator input)
|
Input Voltage Range
|
Three phase 380VAC(-15%~30%)
|
Output specification
|
Rated output voltage
|
3PH 380VAC
|
Output frequency
|
0~500.00Hz(Default 0~50.00Hz)
|
Fault protection
|
Built-in Protection
|
Protection of light load, over-current, over-voltage, output phase-lose, under-load, under-voltage, short circuit, overheating, water pump run dry etc.
|
Keypad display
|
LED display
|
Highlight LED digital tube displays the inverter information
|
LCD display
|
LCD displays inverter information
|
Others
|
Application Site
|
No direct sunshine, no dust, corrosive gas, combustible gas, oil mist, steam, dripping or salinity etc.
|
Altitude
|
0~2000m, Derated use above 1000m,per100m, the rated output current decrease 1%.
|
Environment Temperature
|
-10℃~50℃ (Environment Temperature be 40℃~50℃, please keep derated use.)
|
Humidity
|
5~95%,non-condensation
|
Vibration
|
less than 5.9 m/s2(0.6g)
|
Storage Temperature
|
-20℃~+70℃
|
Efficiency
|
Rated Power Run≥93%
|
Installation
|
Wall or rail mounting
|
Cooling
|
Forced Air Cooling
|