    Before judging the abnormality... about the alarm when the power is turned on.

EMST input of interface CN2: emergency stop (pin 3), OTP · OTM input: travel limit (pin 5 and 6) is not connected,

Although the alarm occurs when the power is turned on, it is not the fault of the drive body.

The factory default setting of EMST input and OTP · OTM input is contact B.

Implement wiring processing, or change to contact A according to the following steps to remove the alarm.

NSK M-EDC-PS3090AB502

INPUT:1PH 200-240V 2.2A 50/60Hz

OUTPUT:3PH 200-240V 4.0A 1-50Hz