MODEL
|
PDF-350-12
|
PDF-350-24
|
PDF-350-48
|
OUTPUT
|
DC Output
|
12V
|
24V
|
48V
|
Rated Current
|
25A
|
14.6A
|
7.3A
|
CurrentRange Note 1
|
0~25A
|
0~14.6A
|
0~7.3A
|
Peak Load
|
30A(last 60S, 230Vac input)
|
18A(last 60S, 230Vac input)
|
9A(last 60S, 230Vac input)
|
Ripple and Noise Note 2
|
0~70℃
|
≤150mV
|
≤240mV
|
≤240mV
|
-30℃
|
≤240mV
|
≤480mV
|
≤480mV
|
Voltage ADJ. Range
|
11.6~13.2V
|
23.5~26.5V
|
47~52.8V
|
Voltage Accuracy
|
±3.0%
|
Line Regulation
|
±1.0%
|
Load Regulation
|
±2.0%
|
Set-up Time
|
≤3S (230Vac input, Full load)
|
Hold up Time
|
≥10mS (230Vac input, Full load)
|
Temperature Coefficient
|
±0.03%/℃
|
Overshoot and Undershoot
|
<5.0%
|
INPUT
|
VoltageRange
|
90Vac~264Vac
|
FrequencyRange
|
47Hz--63Hz
|
Power Factor(Typical)
|
PF>0.98/115VAC PF>0.95/230VAC
|
Efficiency ( Typical)
|
≥90% (230Vac input, full load)
|
≥90% (230Vac input, full load)
|
≥93% (230Vac input, full load)
|
AC Current (max.)
|
<5.0A
|
Inrush Current (Typical)
|
<40A@230Vac <20A@115Vac Cold start
|
Stand by power consumption
|
<5W
|
Leakage Current
|
Input—output:<0.25mA Input—PG:<3.5mA
|
PROTECTION
|
Over Load
|
26.3~37.5A, constant current
|
15.33~21.9A, constant current
|
7.7~11A, constant current
|
Over Power
|
315~450W, constant current
|
368~525W, constant current
|
368~525W, constant current
|
Over Voltage
|
13.8~16.0V
|
26.5~36V
|
50~63V
|
Constant voltage, auto recovery
|
Over Temperature
|
95℃±5℃(detect on temperature controller) shut down o/p voltage, auto
recovery after temperature goes down to50C
|
Short Circuit
|
Long-term mode, auto
recovery
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-30℃~70℃; 20%~90%RH No condensing(refer to the derating curve)
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
SAFETY &EMC
(Note 3)
|
Safety Standards
|
UL60950-1 ;EN60950-1:2006
|
Withstand Voltage
|
Primary-Secondary: 3.0KVac/10mA
.Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.
|
Isolation Resistance
|
10Mohms
|
EMI Conduction & Radiation
|
Compliance to EN55022,FCC PART 15 Class B
|
Harmonic current
|
Compliance to EN61000-3-2,CLASS
D
|
EMSImmunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11;
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 200,000Hrs (25℃, Full load)
|
Dimension (L*W*H)
|
199×99×50mm
|
Packing
|
12PCS/CTN, 13.5KGS, 0.04CBM
|
Cooling method
|
Free air convection
|
NOTE
|
1. All parameters NOT specially mentioned are measured
at rated input, rated load and25℃of ambient temperature.
2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1
uF & 47uF parallel capacitor.
3.The power supply is considered as
a component which will be installed into a final equipment. The final
equipment must be re-confirmed that it still meets EMC directives. For
guidance on how to perform these EMC tests, please refer to “EMI testing of
component power supplies” on https://www.powerld.com
|