PDF-500-X



  • Dimension170×120×83.5mm
  • ApprovalN
  • Conformal CoatingY
  • PFCY
  • Output12, 15, 24, 27.5, 48
  • Input90-264Vac
  • Wattage (W)500

Ø  Universal AC input/ Full range

Ø  Built-in active PFC function,PF>0.95

Ø  Withstand 300VA surge input for 3 secs.

Ø  Built-in cooling Fan ON-OFF control

Ø  Output protections: OLP/OVP/OTP/SCP

Ø  All using105℃long life electrolytic capacitors.

Ø  Build-in remote sense function

Ø  Build-in remote ON-OFF control

      Ø 3 years warranty

MODEL

PDF-500-12

PDF-500-15

PDF-500-24

PDF-500-27.5

PDF-500-48

OUTPUT

DC Output

12V

15V

24V

27.5V

48V

Rated Current

41.7A

33.3A

21A

18.2A

10.5A

Current Range     Note 1

0~41.7A

0~33.3A

0~21A

0~18.2A

0~10.5A

Ripple and Noise   Note 2

0~70

<150mV

<150mV

<200mV

<200mV

<240mV

-20~0

<240mV

<240mV

<400mV

<400mV

<480mV

Voltage ADJ.  Range

11.6V-13.2V

14.5~16.5V

23.5V-27.2V

26.0V-30.0V

46V-54V

Voltage Accuracy

±2.0%

±2.0%

±2.0%

±2.0%

±2.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Set-up Time

2.0S (115Vac input, Full load); 2.0S (230Vac input, Full load)

Hold up Time

10mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

88Vac~264Vac

Frequency Range

47Hz~63Hz

Power Factor(Typical)

PF0.98/115VAC    PF0.95/230VAC

Efficiency ( Typical)

115Vacinput

85%

86%

87%

88%

89%

230Vacinput

88%

89%

90%

91%

92%

AC Current (max.)

5.5A

2.5A

Inrush Current (Typical)

<20A@115Vac    <40A@230Vac      Cold start

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA

PROTECTION

Over Load

110%~150% of rated output current, constant current limiting for 3S,then hiccup mode, auto recovery

Over Voltage

115%~150% of rated output voltage,constant voltage

Over Temperature

95+10(detect on heatsink of power transistor);shut down,auto recover after the temperature goes down

Fan ON/OFF Control

Output load>65% rating or inside temperature >55, FAN ON

ENVIRONMENT

Operating amb. Temp. & Hum.

-20~70;  20%~90%RH  No condensing(refer to the derating curve)

Storage Temp. & Hum.

-25~85;  10%~95%RH  No condensing

SAFETY&EMC Note 3

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVDC;10mA.

Isolation Resistance

100M ohms

EMI Conduction& Radiation

Compliance to EN55022, EN55024, FCC PART 15   CLASS B

Harmonic Current

Compliance to EN61000-3-2CLASS D

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25, Full load)

Dimension  (L*W*H)

170×120×83.5mm

Packing

6PCS/CTN, 12KGS, 0.04CBM

Cooling method

Cooling by forced air (built-in DC fan)

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25of ambient temperature.

2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.


We focus on your industrial power supply project needs,  Offering reliable quality and high cost-effective products is always our top priority. Effective Communication within 24 hours.


Product Tags 24v power supply          Conformal Coating for Power Supplies          Conformal coated power supplies         

INQUIRY

Contact us for all information about the product


click here to leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.