MODEL
|
PDF-500L-24
|
OUTPUT
|
DC Output
|
24V
|
Rated Current
|
21A
|
Ripple and Noise
Note 2
|
0-70℃
|
≤240mV
|
-30℃
|
≤480mV
|
Voltage ADJ. Range
|
23.5~26.5V
|
Voltage Accuracy
|
±3%
|
Line Regulation
|
±1%
|
Load Regulation
|
±2%
|
Set-up Time
|
≤3S (230Vac input, Full load)
|
Hold up Time
|
≥10mS /(230Vac input, Full load)
|
Temperature Coefficient
|
±0.03%/℃
|
Overshoot and Undershoot
|
<5.0%
|
INPUT
|
Voltage Range
|
90Vac~264Vac
|
Frequency Range
|
47Hz--63Hz
|
Power Factor(Typical)
|
PF>0.98/115VAC PF>0.95/230VAC
|
Efficiency ( Typical)
|
≥92% at 230Vac, full load
|
AC Current (max.)
|
<8A
|
Inrush Current (Typical)
|
<20A@115Vac ; <40A@230Vac Cold start
|
Leakage Current
|
Input—output: ≤0.1mA Input—PG: ≤0.75mA
|
Standby power consumption
|
<1.5W
|
PROTECTION
|
Over Load
|
≥25A, ≤31.2A,Constant current limiting for some time(31.2A, last ≥3S) then PS
stop
working for 7S,after 7S,if the load <=rated current, PS will work
normally, auto recovery
|
Over Voltage
|
29~34V, Constant voltage, auto recovery
|
Over Temperture
|
95℃+5℃(detect on
thermal protector temperature);shut down,auto recovery after the temperature
goes down to50℃
|
Short Circuit
|
Long-term mode, constant current, auto
recovery
|
ENVIRONMENT
|
Operating amb. Temp. & Hum.
|
-30℃~70℃; 20%~90%RH No condensing (refer to derating curve)
|
Storage Temp. & Hum.
|
-40℃~85℃; 10%~95%RH No condensing
|
SAFETY
&EMC
(Note 3)
|
Safety Standards
|
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006
|
Withstand Voltage
|
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVdc;≤10mA.
|
Isolation Resistance
|
10M ohms
|
EMI Conduction&Radiation
|
Compliance to EN55022, FCC PART
15 CLASS B
|
Harmonic Current
|
Compliance to EN61000-3-2, class
D
|
EMS Immunity
|
Compliance to
EN61000-4-2,3,4,5,6,8,11; heavy industry level
|
OTHERS
|
MTBF (MIL-HDBK-217F)
|
More than 200,000Hrs (25℃, Full load)
|
Remote control
|
Pls refer to below detailed
description
|
PG signal
|
POWER GOOD warning signal, normal:
5+0.3V; abnormal: 0-0.8V
|
Dimension (L*W*H)
|
218*116.5*40.7mm
|
Packing
|
6PCS/CTN, 8.0KGS, 0.04CBM
|
Cooling method
|
Fored air cooling(Built-in DC Fan, controlled by temperature
and load)
|
Fan working: temperature controller up to 60±10℃or Output Current >10±1A
Fan stop working: temperature controller down to 40±10℃or Output Current<9±1A
|
NOTE
|
1. All parameters NOT
specially mentioned are measured at rated input, rated load and25℃of ambient temperature.
2. Measured at 20MHz of
bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The power supply is considered as a
component which will be installed into a final equipment. The final equipment
must be re-confirmed that it still meets EMC directives. For guidance on how
to perform these EMC tests, please refer to “EMI testing of component power
supplies” on http://www.powerld.com.
|