ZLT-SP2, to determine the mechanical strength of the connector, accordance with IEC60320 1 figure 19 and clause 23.3,
ZLT-GP, to determine the fixed structure reliability of surface type socket outlets, in accordance with IEC60884 1 clause 24.3
ZLT-CS1, to test plugs and socket-outlets, cable couplers and appliance couplers, according to IEC 60884-1 figure 16 and clause 20.
ZLT-CS2, according to IEC 60884-1 figure 16 and clause 20. 2 working station for 2 specimen simultaneously.
ZLT-CS3, according to IEC 60884-1 figure 16 and clause 20. 3 working station for 3 specimen simultaneously.
ZLT-SW, to test switches having rated resistive-load currents up to 16 A,in accordance with IEC60669-1 clause 18 and 19
ZLT-GT4, similar to ZLT-GT2, but of larger dimensions for testing of accessories for vacuum cleaners, according to IEC60312 figure 16.
ZLT-GT3, similar to ZLT-GT2, but according to BS1363 figure 20.
ZLT-GT2, is to determine the mechanical strength of electrical appliances or electrical components in accordance with IEC60068-2-32 Amendment 2
similar to ZLT-GT2, but according to IEC60730 figure 5.
ZLT-LJ4, to torque test of plugs and connectors provided with a flexible cable,rated current 13A to 400A, according to IEC62196 clause 25.3 and table 19.
click here to leave a message