IEC 60529 IPX3 IPX4 Spray Nozzle
ZLT-JL1. For checking the protection against ingress of water to prove the degrees of protection with the second characteristic numerals 3 “Protected against Spraying Water” and 4 “Protected against Splashing Water”, in accordance with IEC60529 figure 5, IEC60335 clause 15.1.1, IEC60598.
IEC 60529 IPX5 & IPX6 Water Jet Nozzle
ZLT-JL2. For checking the protection against ingress of water to prove the degrees of protection with the second characteristic numerals 5 “Protected against water jets” or 6 “Protected against powerful water jets”, in accordance with IEC60529 figure 6, IEC60335-1 clause 15.1.1, EN60950, IEC60598 figure 8.
IEC 60529 Drip Box
ZLT-DB. For checking the protection against water to prove the degrees of protection with the second characteristic numerals 1 “Protection against water drops” and 2 “Protection of a specimen in a position of tilt against water drops” According to IEC60529 Fig 3 Table 8, IEC60335-1 clause 15.1.1, IEC60947-1 Annex C.14.1, IEC60598-1 clause 9.2.3
IEC 60529 Oscillating Tubes Device
ZLT-DP. For checking the protection against water with spray nozzle of 0,4 mm bore are used to prove the degrees of protection for the second characteristic numerals 3 and 4 “Protection against Spraying Water” resp. “Protection against splashing Water”. According to IEC60529 figure 4, IEC60598 clause 9.2.5, IEC60947.
IEC 60529 Turntable Test Device
ZLT-TD. To carry the specimens when determining the protection against water, according to IEC60529 figure 4, IEC 60335-1 clause 15.1.1, IEC60598 clause 9.2.4 and 9.2.5.
IEC 60529 IPX Water Test Whole System
ZLT-IPX1-6. For checking the protection against ingress of water to prove the degrees of protection with the second characteristic numerals 1 to 6, in according to IEC60529 IPX1-6.
Creepage Distances Gauges
ZLT-CK. For gauging the creepage and clearance distances in dead state between parts under voltage in the operating conditions as well as between touchable metal pieces and parts under voltage in the operating conditions. e. g. in installation material, switchgears, plugs, socket-outlets and electric appliances
Mandrel Test Apparatus
ZLT-BM1. The Mandrel is used to test non-separable thin sheet material. Constructional requirements with regard to Protection against Electric Shock for IEC61558-1 Figure6, IEC60065 Figure14 16 and IEC60950 Annex AA.
Dielectric Strength Test Instrument
ZLT-KQ1. To test the surge strength according to IEC60065 figure 6 and UL1310 clause 40.2,
75 and 20 Pounds Force Test Instrument
ZLT-F75P. For resistance to crushing on direct plug-in units, according to UL1310-2005 clause 46.5.1,UL1310-2005 clause 46.4.2.
Test Chain
ZLT-P. To check the short-circuit protection,according to IEC50598 clause 4.26.3.
Expanded Metal Spacer
ZLT-S1. according to IEC 60598 clause 9.2, to tests for ingress of dust, solid objects and moisture,
Crush Test Flat Surface
According to IEC 62368:4.8.4.6, a flat surface measuring approximately 100 mm by 250 mm for crush test.
Dust Test Chamber
In accordance with IEC60529/2001 figure 2 and IEC 60598 etc,