In a system with 2000 feet of data line the propagation delay can be
calculated by multiplying the cable length by the propagation velocity
of the cable. This value, typically 66 to 75% of the speed of light (c), is
specified by the cable manufacturer.
A round trip covers 4000 feet of
cable. Using a propagation velocity of 0.66 × c, one round trip is
completed in approximately 6.2 µs. Assuming the reflections will damp
out in three "round trips" up and down the cable length, the signal will
stabilize 18.6 µs after the leading edge of a bit
MAXON WATKINS JOHNSON 089714-000
METEOR/RGB PCI 571-03 | MATROX | PLC MODULE
sales3@amikon.cn
There are several methods of terminating data lines. These include
parallel termination, bidirectional termination and AC termination.
Parallel termination is the addition of a single termination resistor
somewhere along the communications line
Allen Bradley
|
|
1756-OB32/A
|
Allen Bradley
|
|
1756-L55M13/A 1756-L55/A 1756-M13/A
|
Allen Bradley
|
|
1756-OW16I/A
|
Allen Bradley
|
|
NX70-BASE03-CH
|
Allen Bradley
|
|
1606-XL240E
|
Allen Bradley
|
|
1771-IAD/D
|
Allen Bradley
|
|
1771-OBN/B
|
Allen Bradley
|
|
1771-0D16/B
|
Allen Bradley
|
|
1747-AIC
|
Allen Bradley
|
|
1747-C11-A
|
Allen Bradley
|
|
1771-NOV/C
|
Allen Bradley
|
|
1771IBN C
|
Allen Bradley
|
|
NX70-XY32-CH
|
Allen Bradley
|
|
NX70-X32D1-CH
|
Emal:sales3@amikon.cn
Are you looking for a suitable sustainable partner to ensure your industrial electronics run smoothly or in the event of a failure?
If so, then Moore Automation is your best choice.