Xiamen Blushing Sauce E-Commerce Co., Ltd. is a professional service provider in the field of industrial automation parts. We mainly provide PLC modules, DCS cards, ESD system cards, vibration monitoring system cards, turbine control system modules, gas generator components, and we have established close cooperative relations with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and provide equipment and spare parts from different countries and manufacturers to solve your troubles.

All products

ABB AI950B (TI4-B) 3KDE175522L9500 AI950B Temperature Input (TI4-B), supporting Pt100, Pt1000and Ni100 in 2-/3-/4- technology. mA.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI950B Temperature Input (TI4-B), supporting Pt100, Pt1000and Ni100 in 2-/3-/4- technology. Thermocouples B, E, J, K, L, N, R, S, T, U, mV. Isolated inputs channel by channel. Email:sean@xmbse.cn

6ES7 321-1FF01-0AA0 ▏Siemens Digital Input Module

Digital Input Module Siemens 6ES7 321-1FF01-0AA0 Email: Sean@xmbse.cn

6DL1193-6BH00-0RM0 CARRIER MODULE IM REDUNDAN

CARRIER MODULE IM REDUNDANT Email: Sean@xmbse.cn

ABB AI950N (TI4) 3KDE175523L9500 Pt 100, Pt 1000, Ni 100, 0...3kOhms in 2/3/4 wire technique

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units.S900 I/O type N. For installation in safe (= non-hazardous) area. AI950N Temperature Input (TI4), supporting Pt100, Pt1000 and Ni100 in 2-/3-/4-technology. Thermocouples B, E, J, K, L, N, R, S, T, U, mV. Isolated inputs channel by channel. Email:sean@xmbse.cn

IC693PWR321Z ▏GE Fanuc | Power Supply

⭐brand new⭐huge discount ⭐12 Months Warranty

6DL1193-6AR00-0AA0 ET 200SP HA, BUSADAPTER BA 2XRJ4

ET 200SP HA, BUSADAPTER BA 2XRJ45 Email: Sean@xmbse.cn

ABB AI950S (TI4-Ex) 3KDE175521L9500 Pt 100, Pt 1000, Ni 100, 0...3kOhms in 2/3/4 wire technique

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AI950S Temperature Input (TI4-Ex), supporting Pt100, Pt1000 and Ni100 in 2-/3-/4-technology. Thermocouples type B, E, J, K, L, N, R, S, T, U, mV. Isolated inputs channel by channel. Email:sean@xmbse.cn

IS200TBAIH1C ▏GE Fanuc Analog Input Terminal Board

⭐brand new⭐huge discount ⭐12 Months Warranty

6DL1135-6TF00-0PH1 ET 200SP HA, AQ 8XI HAR

ET 200SP HA, AQ 8XI HART Email: Sean@xmbse.cn

ABB AO910B (AO4-B) 3KDE175532L9100 Output signal 0/4...20 mA for actuators

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO910B Analog Output (AO4-B), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

S700VR-EST ▏General Electric Transmission Receiver

⭐brand new⭐huge discount ⭐12 Months Warranty

6DL1136-6AA00-0PH1 ET 200SP HA, F-AI 8xI 2-/4-wire HART H

ET 200SP HA, F-AI 8xI 2-/4-wire HART HA Email: Sean@xmbse.cn

GE P111-6052 MICRO CONTROLLER

⭐brand new ⭐huge discount ⭐12 Months Warranty

IC200PNS002 ▏GE Fanuc Scan Modules

⭐brand new⭐huge discount ⭐12 Months Warranty

6DL1136-6DA00-0PH1 ET 200SP HA, F-DI 16X24VDC

ET 200SP HA, F-DI 16X24VDC Email: Sean@xmbse.cn

ABB AO910N (AO4) 3KDE175533L9100 AO910N Analog Output (AO4), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. AO910N Analog Output (AO4), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

SCHNEIDER HMIGTO2300

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AO910S (AO4-Ex) 3KDE175531L9100 AO910S Analog Output (AO4-Ex), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO910S Analog Output (AO4-Ex), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

Schneider XS630B1MAL2 Telemecanique Inductive Sensor

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AO920B (AO4I-B) 3KDE175532L9200 AO920B Analog Output (AO4I-B), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO920B Analog Output (AO4I-B), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

GE FANUC IC694BEM331A Genius Bus Controller

⭐brand new⭐huge discount ⭐12 Months Warranty

SCHNEIDER ATV320U75N4C Variable Speed Drive

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AO920N (AO4I) 3KDE175533L9200 AO920N Analog Output (AO4I), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units.S900 I/O type N. For installation in safe (= non-hazardous) area. AO920N Analog Output (AO4I), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

GE FANUC IC660BBA105 ▏Analog Output Module

⭐brand new⭐huge discount ⭐12 Months Warranty

SCHNEIDER 140CRA31200C RIO Station Module

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AO920S (AO4I-Ex) 3KDE175531L9200 AO920S Analog Output (AO4I-Ex), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO920S Analog Output (AO4I-Ex), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

GE FANUC IC693MDL310 Input Module

⭐brand new⭐huge discount ⭐12 Months Warranty

SCHNEIDER SPM10KL Power Supply.

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AO930B (AO4H-B) 3KDE175532L9300 AO930B Analog Output (AO4H-B), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. AO930B Analog Output (AO4H-B), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

Circuit Board IS200TTURH1BED ▏General Electric

⭐brand new⭐huge discount ⭐12 Months Warranty

Schneider ATV320U55N4B Variable Speed Drive

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB AO930N (AO4H) 3KDE175533L9300 AO930N Analog Output (AO4H), output signal 0/4...20 mA for actuators.

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type N. For installation in safe (= non-hazardous) area. AO930N Analog Output (AO4H), output signal 0/4...20 mA for actuators. Email:sean@xmbse.cn

IC200PWR001G ▏General Electric DC Power Supply

⭐brand new⭐huge discount ⭐12 Months Warranty

Schneider IC65N/A9F18232/EN 60898-1 Advantage Price

⭐brand new ⭐huge discount ⭐12 Months Warranty

GE IC3600VANB1D Phoenix Controls

⭐brand new ⭐huge discount ⭐12 Months Warranty

Analog Input Module IC660BBA026 ▏General Electric

⭐brand new⭐huge discount ⭐12 Months Warranty

Schneider LC1D12BDC Advantage Price

⭐brand new ⭐huge discount ⭐12 Months Warranty

ABB CI920AB (CIPBA-B) 3BDH000691R1 CI920AB Communication Interface V2.1 (CIPBA-B), for Fieldbus protocol PROFIBUS DP-V1 (IEC 61158)

The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced. The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units. S900 I/O type B. For installation in hazardous area Zone 2. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0. CI920AB Communication Interface V2.1 (CIPBA-B), for Fieldbus protocol PROFIBUS DP-V1 (IEC 61158). Use only CI920AB with the same firmware for redundancy for PROFIBUS DP-V1 (observe Release Notes). Email:sean@xmbse.cn

Showing 12 to 21 of 21 (12 Pages)

click here to leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.